Modify Network Properties

You can modify the properties of a network and its associated properties through the network tree explorer or through Entity Editor. See, Network Tree and Entity Editor.

Modify Network Properties

Table 1. Feature History

Feature Name

Release Information

Description

New Bandwidth Properties

Cisco ONP Release 5.1

Cisco ONP introduces the Statistical Simulation Sigma, Statistical Simulation Margin Sigma, and OSNR Resolution Bandwidth properties in this release. When the ideal OSNR values calculated by Cisco ONP are not feasible to be used at the time of deployment, you can modify the values for these properties to customize OSNR margin, power margin, and G-OSNR values to fix the fiber span issues.

New Network Level Properties

Cisco ONP Release 5.1

Three new Network Level properties are introduced to enable you to customize the core operations of an NCS 2000 Network. These operations ran in the background in the earlier releases. The new properties available under Core Operations as check boxes are:

  • Enable LOGO Algorithm—It runs the Local Optimization Global Optimization (LOGO) algorithm to find the efficient output power setpoint for booster amplifiers. By default, this Enable LOGO Algorithm check box is enabled.

  • Log Enabled—It generates, and stores logs only for selected network topologies. This saves a lot of storage space compared to previous implementations in which logs were automatically generated and saved for all topologies.

  • Ignore Raman Span Checks—It ignores the analysis of Raman spans between ROADM sites. This is useful when designing nonstandard network topologies with more than two Raman amplifiers between ROADM sites. Selecting the check box prevents Cisco ONP from raising an error message when analyzing such topologies.

BOM Customization for the UCS-based SVO Server Application

Cisco ONP Release 5.1

From this release onwards, the BOM does not include any UCS-based SVO server information. It is expected that you add the server PID and quantities manually. Cisco ONP prompts you to add the server by displaying the message "UCS server is not billed in BoM, please add it as needed." in the Messages tab of the Elements tab.

Use this task to modify the properties of the network.

Before you begin

Log in to Cisco ONP Web Interface.

Procedure


Step 1

In the network tree, click the network name.

You can view the basic properties of the network at the bottom of the network tree.

Step 2

Modify the following network properties as required.

Property

Platform

Description

Name

NCS 2000

NCS 1010

Modify the network name as required.

Quick Analysis

NCS 2000

Check the Quick Analysis check box to quickly analyze the network by using a less accurate algorithm.

The quick analysis option does not optimize the DCU and amplifier placement algorithm, hence resulting in an approximate BoM.

To receive an accurate BoM, uncheck the Quick Analysis check box.

DWDM Interfaces

NCS 2000

Cisco ONP supports 100G and 200G transceivers as DWDM interfaces.

This option is applicable only for automatically created waves, when OTN services are present.

  • 100G—The entire network chooses the 100G wavelength for transmission.

  • 200G—The entire network chooses the 200G wavelength for transmission.

If you enable both 100G and 200G options, by default, the entire network chooses the 200G wavelength for transmission. If 200G wavelength is not optically feasible, then it selects 100G automatically for transmission.

Customer Name

NCS 2000

NCS 1010

Enter the customer name.

Project

NCS 2000

Choose ANSI (North American standard) or ETSI (European Telecommunications Standards Institute) from the drop-down list. ANSI networks do not allow you to define SDH (ETSI) service demands. ETSI networks do not allow you to define SONET (ANSI) service demands.

NCS 1010

Displays the type of the project, ANSI, or ETSI. You cannot edit it.

Measurement Unit

NCS 2000

NCS 1010

Select the unit of measurement of span length. The available options are Miles and Km.

A2A Mode

NCS 2000

Choose the A2A (Any to Any) mode. The available options are:

  • A2A_None

  • A2A_FAST

A2A Power Output

NCS 2000

The power output value is based on the chosen A2A mode.

A2A Demand Type

NCS 2000

The demand type is based on the chosen A2A mode.

A2A Channel Type

NCS 2000

Choose the type of channel. You can choose multiple types. The available options are:

  • Contentionless―This property enables an N-degree ROADM node to accommodate N wavelengths of the same frequency from a single add or drop device.

  • Colorless―The colorless property enables tuning of channel wavelengths without changing the optical interface of the port.

  • Colored―The Colored property dedicates a separate port for each wavelength.

SSON

NCS 2000

Indicates whether the network is an SSON network.

Use client Payg

NCS 2000

Check this check box to enable the Pay As You Grow feature on the client cards.

The PAYG feature enables you to implement a cost-effective solution when the wavelength requirements are comparatively less than the maximum capacity of the network. A standard card is configured to work on maximum supported wavelengths, whereas a PAYG license comprises license restricted cards and a base license. So, instead of purchasing a standard card, you can purchase a PAYG license.

Naming Convention Enabled

NCS 2000

(Display only.) By default, the Naming Convention Enabled option is enabled by default for the networks that are created in Cisco ONP, and you cannot edit it. By default, the sides are named from T, S, R, Q, P, O, N, M, L, K, J, I, H, G, F, E, and index, depending upon the used Scalable Upto parameter.

  • You can import a mpz network without naming convention enabled, but the Cascaded SMR option remains disabled.

  • You cannot edit the label name of the side.

System Release

NCS 1010

NCS 1010

Displays the system release of the NCS 1010 node in the network.

NCS 4K

NCS 4000

Displays the system release of the NCS 4000 node in the network.

NCS 2K

NCS 2000

Displays the system release of the NCS 2000 node in the network.

NCS 1K (Available only on the SSON network)

NCS 1004

Displays the system release of the NCS 1004 node in the network.

Previous NCS 2K (Available only on the Release upgraded network)

NCS 2000

Displays the system release of the NCS 2000 node in the network, before the Release upgrade.

Previous NCS 1010 (Available only on the Release upgraded network)

NCS 1010

Displays the system release of the NCS 1010 node in the network, before the Release upgrade.

SVO

NCS 2000

Choose the type of network management solution. The available options are:

  • Line Card―Chooses SVO card.

  • Server―Chooses SVO application that is hosted on a server. From Release 5.1, if you select Server, the PID for the server does not appear in the BoM report. A warning message "UCS server is not billed in the BoM, please add it as needed." appears in the Messages tab of the Elements tab.

  • Auto―Chooses SVO card as default, for SVO solution.

Network Application Configuration

Use Coordinates Distance

NCS 2000

NCS 1010

Check this check-box to use the x and y coordinate to calculate the fiber length.

Link-Tuner

NCS 1010

Check this check-box to enable the link-tuner

Note

 

When you generate a NetConf XML file for the C+L and C+L Futuristic R7.9.1 networks, Link-Tuner appears as disabled in the NetConf XML file.

Raman-Tuner

NCS 1010

Check this check-box to enable the Raman tuner.

Raman Gain Auto Tuner

NCS 1010

Check this check-box to enable the Raman gain auto tuner.

Note

 

When you generate a NetConf XML file for the C+L and C+L Futuristic R7.9.1 networks, Raman Gain Auto Tuner appears as disabled in the NetConf XML file.

Raman Amplification

NCS 1010

Choose whether Raman amplification is Auto or User Forced.

Maximum Auto Ramans

NCS 1010

Choose the maximum number of Raman enabled links on an end to end circuit path. The available options are 1–3.

Spectrum Utilization

NCS 1010

By default, the spectrum utilization is Short Path First. This field is noneditable.

Band Type

NCS 1010

Choose the band type. The available options are:

  • C-Band

  • C+L Futuristic

  • C+L

Note

 

After creation of a network, you can change the network band type, if required.

Tm Ordering Strategy

NCS 1010

Choose default routing priority for circuits based on minimum distance (Length) or minimum number of hops (Hop). By default, is minimum number of hops.

Optical Algorithm Options

Stat Sim Sigma

NCS 2000

NCS 1010

Choose the Statistical Simulation Sigma (Stat Sim Sigma) value. The available options are 0, 1, 2, and 3. The default value is 3.

The Stat Sim Sigma value is used in calculating the SOL G-OSNR, EOL G-OSNR, SOL Power, EOL Power, SOL OSNR margin, EOL OSNR margin, SOL Power margin, and EOL Power margin displayed in the Optical Results page. The lower the value you choose, the better is the OSNR and power margins.

You can edit this value in Design mode, and Upgrade mode (after unlocking the network). Analyze the network and check the Optical Results page to view the updated OSNR and Power values.

Stat Sim Margin Sigma

NCS 2000

NCS 1010

Choose the Stat Sim Margin Sigma value. The available options are 0, 1, 2, and 3. The default value is 3. You can edit this value in all modes (Design, Analyze (locked state), Upgrade, and Release Upgrade). To view the OSNR margin and power values that get updated based on the value you selected, reopen the Optical Results page.

Core Operations

Enable LOGO Algorithm

NCS 2000

By default, this property is enabled. In non-SSON networks, it is editable. In the SSON network, it is noneditable. This algorithm enables the Cisco ONP to automatically find the optimal output power setpoint for booster amplifiers within a fiber span.

Log Enabled

NCS 2000

NCS 1010

Check this check-box to enable generation and storage of network logs.

Ignore Raman Span Checks

NCS 2000

Check this check-box to enable network analysis to ignore Raman span checks.

Ignore APC Penality

NCS 1010

By defult this check-box remains checked, when the Enable Special Settings check-box is checked. Automatic Power Control (APC) penality occurs due to the inherent error in regulating the set-point for power. This penalty is considered while calculating the OSNR and power margin. When this property is enabled, this penalty is ignored during the calculation and thus providing accurate optical results.

Step 3

Click Update.

Step 4

To modify the advanced properties of the service, click Show Advanced Properties or choose Network > Entity Editor.

Step 5

In the Entity Editor window, click the Site tab.

Step 6

Click the network, and modify the properties in the right pane.

Step 7

Click Update.


Modify Site Properties

Use this task to modify the properties of the site.

Before you begin

Table 2. Feature History

Feature Name

Release Information

Feature Description

Shared SMR Port

Cisco ONP Release 4.2

You can enable the Colored Add/Drop property. This feature supports the use of contentionless and colored demands that are connected to the same port of an SMR card. With the Shared SMR Port enabled, you can create and validate the contentionless and colored configuration on a 16-degree SMR-20 node.

Log in to Cisco ONP Web Interface.

Procedure


Step 1

In the network tree, expand Sites, and click a site.

You can view the basic properties of the site at the bottom of the network tree.

Step 2

Modify the following site properties as required.

Property

Platform

Description

General

Name

NCS 2000

NCS 1010

Enter the site name, either alphanumeric or numeric.

Type

NCS 2000

Choose the type of site. For example, ROADM, OLA, PASSTHROUGH, or a Traffic site.

  • You can add a passthrough site as a place holder. You cannot add services or waves to this site and therefore cannot generate the report. Later, you can convert the passthrough site to a ROADM, OLA, or the Traffic site in the design mode.

  • OLA is an optical line amplifier site that is used only for amplification. You cannot add service or waves on this site.

  • You cannot add a Traffic site of the type 4K-2K into an SSON network.

NCS 1010

Choose the type of site. For example, ROADM, OLA, or PASSTHROUGH.

Node Type

NCS 2000

The default value is FLEX NG-DWDM for all nodes. This field is non-editable.

Equipment Configuration

NCS 2000

Choose the configuration from the drop-down list. This option is available only for the Traffic site. The available options are:

  • Large CO - NCS 4016

  • Small Site - NCS 4016

  • Small Site - NCS 4009

Traffic Type (only for Traffic site)

NCS 2000

Choose the traffic type. The available options are:

  • 4K_1K_2K (for SSON)

  • 1K_2K (for SSON)

  • 4K_2K (non- SSON)

SSON

NCS 2000

Indicates whether the network is an SSON network.

SVO

NCS 2000

This property is noneditable at site level. This property enables you to select SVO card as Server or Line card at the network level.

Layout

Chassis Type

NCS 2000

Choose the type of chassis. Chassis type is supported for all the sites except passthrough.

The available options are:

  • M6 Chassis

  • M15 Chassis

  • Auto

    M15 is the default option when you choose Auto.

Power Supply

NCS 2000

NCS 1010

Choose the type of Power Supply. The available options are Auto, AC Power, and DC Power.

The default option is Auto.

C Band

Structure

NCS 2000

Choose the type of the site. The available options for ROADM and Traffic sites are:

  • Multi-degree

  • Line

  • Terminal

For OLA and PASSTHROUGH, it is Line, and you cannot edit it.

NCS 1010

Choose the type of the site. The available options for ROADM sites are:

  • Multi-degree

  • Line

  • Terminal

For OLA and PASSTHROUGH, it is Line, and you cannot edit it.

Functionality

NCS 2000

Displays the site functionality. Following is the functionality available for each type of sites:

  • Optical Cross Connect (OXC) for ROADM and traffic site

  • Auto or Line Amplifier for OLA site, Cisco ONP downgrades OLA site to passthrough if OLA is not required

  • Passthrough for passthrough site

NCS 1010

Displays the site functionality. ROADM is the default functionality for all site types.

Scalable up to Degree

NCS 2000

This parameter determines the maximum number of degrees, ducts, or line sides that can be supported by the site.

For NCS 2000 site, the available options are 2, 4, 8, 12, and 16. The default option is 4. The network is scalable up to 16 degrees for ROADM and Traffic sites. Choose 2 to have a LINE ROADM site.

For OLA, the value is 2 and is noneditable .

NCS 1010

For NCS 1010 site, the available options are 7, 9, 15, 17, 23, 25, and 31.

Site Type

NCS 2000

Choose the type of site. The available options are:

  • Auto

    Note When you choose Auto, the default option is SMR-20.

  • SMR-20

  • SMR-9

The Site type is Line for the OLA site.

NCS 1010

For NCS 1010 site, the only option is OLT, and it is not editable.

L0 Platform

NCS 2000

NCS 1010

Displays the platform. For example, NCS 1010 or NCS 2000.

Step 3

Click Update.

Step 4

To modify advanced properties of the site, click Show Advanced Properties, or choose Network > Entity Editor.

Step 5

In the Entity Editor window, expand Sites under the network tree, choose the site, and modify the following properties that are displayed in the right pane. For more information on entity editor, see Entity Editor.

Properties

Platform

Description

General

CLLI Code

NCS 1004

NCS 2000

NCS 4000

Enter a string holding the CLLI code.

Site Address

NCS 2000

NCS 1010

Enter the site address.

Evolved Mesh

NCS 2000

By default, this option is unchecked. When you enable this feature on the network, it is automatically enabled on the associated sites of the network.

Status

NCS 2000

Displays the status of the network. It shows whether the network is Up or Down.

Weight Lbs

NCS 1004

NCS 2000

NCS 4000

Displays the weight of all the units of the site, in pounds.

Node Protection

NCS 2000

Choose the Node Protection. The available options are:

  • Same shelf

  • Separated shelves

Mpo16Lc

NCS 2000

Displays the fan-out module. The default option is MF-MPO-16LC.

The MPO-16 to 16-LC fan-out module is a double slot module with one MPO-16 connector (COM) and eight LC duplex connectors. The MPO-16 connector is compatible with the SMR20 FS EXP and 16-AD-CCO FS units.

Mpo16ToMpo8

NCS 2000

Choose the required Mpo16 to Mpo8 converter. The available options are:

  • MPO16ToMPO8Cable

  • MF-2MPO_ADP

MPO Cable

NCS 1010

Choose the required Mpo cable. The available options are:

  • Auto

  • 16MPO-MPO

  • 24MPO-MPO

Cascaded SMR

NCS 2000

Enable this option to add Layer-2 contentionless sides.

Flex Spectrum

NCS 2000

By default, this check-box remains checked for newly created network. You cannot edit it.

Grooming Site

NCS 2000

NCS 4000

When you enable this option, it indicates that OTN traffic can be groomed at this site.

MR-MXP BreakOut Cable

NCS 2000

Check this check box to use the ONS-MPO-MPOLC-10 breakout cable to interconnect the client ports of the MR-MXP card with the NCS2K-MF-MPO-20LC passive module.

8X10G-FO

NCS 2000

Check this check box to use the NCS2K-MF-8X10G-FO passive module only for 10G on the client-side of the NCS2K-400G-XP card. By default, this passive module is enabled.

Band Type

NCS 1010

Choose the required band type for NCS 1010 R7.9.1.

Bill of Material

License Suite

NCS 1010

Choose whether the License Suite is Essential (RTU +SIA3) or Advanced (RTU +SIA3).

Enable NCS

NCS 2000

This feature enables NCS features on all sites in the network.

Use PAYG

NCS 2000

The Pay As You Grow (PAYG) functionality significantly reduces the initial setup cost and enables the purchase of another wavelength capacity on a need basis.

PAYG enables port-based cost or licensing for SMR-9 and SMR-20 cards.

Connection Verification

NCS 2000

Enable this check box to:

  • Validate the correct optical interconnection between the optical cards inside a Flex ROADM.

  • Measure the insertion loss of the external passive path.

  • Validate the quality of the connections to the patch panel.

  • Check if the insertion loss is within expected value.

The following cards support connection verification:

  • SMR20 FS CV

  • MF-DEG-5-CV

  • MF-MPO-16LC-CV

  • MF-UPG-4-CV

New FS-SMR PID

NCS 2000

By default, this check-box remains checked for newly created network. You cannot edit it. This option enables displaying of new SMR-20 PID in the BOM page.

You can enable this option when you unlock an mpz network where SMR-20 is selected, during upgrade or release upgrade.

Layout

Chassis Type

NCS 2000

Choose the type of chassis. The available options are:

  • M6, and M15 Chassis for OLA

  • M6 Chassis for ROADM and Traffic

  • M15 Chassis for ROADM and Traffic

  • Auto for all nodes

Note

 

Chassis type is not supported for the passthrough site.

Power Supply

NCS 2000

Choose the type of Power Supply.

For NCS 2000 site, the available options are based on the chassis type:

  • Auto for all type of chassis

  • AC Power, DC power for M15 and M2 chassis

  • AC Power, DC Power, AC2 Power, DC40 Power, and DC20 Power for M6 chassis

NCS 1010

The options available for NCS 1010 site are Auto, AC Power, and DC power.

Controller Card

NCS 2000

Choose the type of the controller card.

For NCS 2000 site, the default controller card is TNCS-2. The available options are based on the chassis type chosen. By default, controller cards that are supported by M15 chassis are listed. The available options are:

  • Auto

  • TNC/TSC, TNC-E/TSC-E, TNCS, TNCS-0, TNCS-2, and TNCS-20 for M2 chassis

  • TNC/TSC, TNC-E/TSC-E, TNCS, TNCS-0, TNCS-2, and TNCS-20 for M6 chassis

  • TNCS, TNCS-0 TNCS-2, TNCS-20 for M15 chassis

NCS 1010

The following options are available for NCS 1010 site:

  • Auto

  • NCS1010-CNTRL-K9

Redundant Controller Card

NCS 2000

NCS 1010

Choose whether to use a redundant controller card.

Layout Template

NCS 2000

Choose the required layout template.

Note

 

After the chosen layout template is applied, all layout properties will be reset and disabled.

Note

 

After design analysis, if the applied layout template is not considered for card placement in the layout, check for the error message (non- critical) under the Elements > Messages tab. If you see a template-related error which indicates that there is a mismatch between the cards that are defined in template and the cards that are created on the site, perform the following:

  • Export the template from the Layout page, and modify it as required.

  • Import the modified template using the Manage > Layout Template option.

  • Switch to Design mode and apply the template to the site using the Entity Editor.

  • Reanalyze the network to get the correct layout populated.

UTS AC Power Cables

NCS 2000

NCS 1010

Choose the type of cables to be used for the AC power supply. Cables are listed based on the country type and the Chassis type selected.

Redundant Power Scheme

NCS 2000

Choose the redundant power scheme from the drop-down list to configure the number of working and protected power units for the chassis.

For NCS 2000 site, the options available are based on the chassis type. For M15 chassis, the options available are 1+0, 1+1, 2+0, 2+1, 3+0, 3+1, 2+2, 3+1 is the default redundancy power scheme for M15 DC chassis and 2+2 is the default redundancy power scheme for M15 AC chassis. For example, if you choose 3+1 redundant power scheme, there are 3 working power units and 1 protected power unit.

For M6 chassis, the options available are Auto, Yes, and No.

NCS 1010

For NCS 1010 site, The options available are Auto, 1+0, and 1+1.

Raman Adapter Share

NCS 2000

This option is available only for the OLA site. By default, this check box remains checked. This option indicates that MF-2LC-ADP can be shared with EDRA amplifiers and not with RAMAN amplifiers irrespective of the default selection.

ECU Type

NCS 2000

Choose the External Connection Unit (ECU) type from the drop-down list. The options available are based on the chassis type. By default, the ECU applicable for M15 is listed.

  • ECU—Has 12 USB 2.0 ports and supports IEEE1588v2 PTP, time-of-day (ToD), and pulse-per-second (PPS) inputs.

  • ECU-S—Similar to ECU except that it has eight USB 2.0 ports and two USB 3.0 ports.

  • ECU60-S—Variant of ECU-S introduced for the NCS 2006 when the shelf is powered at –60VDC nominal input voltage.

ECU-S and ECU60-S are supported only for M6 chassis.

MF Unit

NCS 2000

Choose the mechanical frame for the passive optical modules from the drop-down list. The options available are Auto, MF-6RU/MF-10RU, and MF-1RU.

  • The NCS2K-MF-1RU has four slots for the passive optical modules.

  • The NCS2K-MF-6RU supports up to 14 single-slot passive optical modules such as any combination of NCS2K-MF-DEG-5, CS2K-MF-UPG-4, or Connection Verification (CV) units.

  • The NCS2K-MF10-6RU supports up to 10 double-slot passive optical modules such as NCS2K-MF-MPO-16LC=.

NCS 1010

For NCS 1010 site, the available options are Auto, MF-4RU, and MF-1RU.

Chassis Disaggregation

NCS 2000

If you check this check-box, ROADM, and transponder cards are placed in different chassis.

Map

X Coordinate

NCS 2000

NCS 1010

It represents the longitudinal location of the site. Longitude can be positive or negative (-180 to 180). Negative is west of Greenwich, and positive is eastward.

Y Coordinate

NCS 2000

NCS 1010

It represents the latitudinal location of the site. Latitude can be positive or negative (- 90–90), north and south of the Equator.

Position Lock

NCS 2000

NCS 1010

Check this check box to lock the site position on the map.

C Band

Shared SMR Port

NCS 2000

Check this check box to connect Contentionless unit 16-AD-CCOFS and Colored unit MD-48-ODD/Even to the same MPO port of SMR-20. When Shared SMR port is enabled, MD-48-ODD/EVEN unit connects to the specific side of SMR-20 through MPO-8LC and UPG-4 instead of directly connecting to SMR-20 through MPO-16LC.

Note

 
Shared SMR port becomes disabled, if
  • Degree Mesh Type property is PPMESH8-5AD

  • Or, Site Type property is SMR-9 and Scalable Upto Degree property is 8

Degree Mesh Type

NCS 2000

Choose the mesh type for Flex NG-DWDM site. The available options are:

  • DEG-5/UPG-4

  • PPMESH8-5AD

DEG-5/UPG-4 is the default value.

Degree Type

NCS 1010

Displays the type of degree. For example, BRK-8.

Pre Equip Degree

NCS 2000

This parameter determines the number of degrees to be considered for the site hardware placement on day 0.

For NCS 2000, the values can be None, Auto, 4, 8, 12 or 16. The default option is None. If you choose None, only the sides that are present in the Cisco ONP GUI are shown. The values in the drop-down list are populated based on the value of Scalable Upto Degree parameter.

NCS 1010

For NCS 1010 site, the options available are Yes and No.

SVO

Chassis License Flush Out

NCS 2000

Allows you to flush out the existing chassis license and purchase new chassis license.

SVO Pluggables

NCS 2000

You can choose one of the following options from the drop-down list. When you choose Auto, ONS_SC+-10G_SR is the default option.

  • Auto

  • ONS-SC +- 10G-SR

  • ONS-SC +-10G-LR

Note

 

The SVO pluggables are not applicable for UCS-based SVO network design.

Cisco NMS

SVO Full License

NCS 2000

Enable this check box to add High Availability (Feature and License), Connection Verification license, Flex Spectrum license, and OTDR license packaged in it.

High Availability

NCS 2000

Enable this check box to add the High Availability feature to the license package.

Connection Verification License

NCS 2000

Enable this check box to add the Connection Verification feature to the license package.

SVO Flex Spectrum License

NCS 2000

Enable this check box to add the Flex Spectrum feature to the SVO license package. For SSON networks, Flex Spectrum license is enabled by default.

OTDR License

NCS 2000

Enable this check box to add the OTDR feature to the license package.

3rd party NMS

3rd party Full License

NCS 2000

Enable this check box to add NBI (North Bound Interface), Alarm Correlation, Performance Monitoring, and Circuit Provisioning features to the license package.

NBI

NCS 2000

Enable this check box to add the NBI feature to the license package.

Alarm Correlation

NCS 2000

Enable this check box to add the Alarm Correlation feature to the license package.

Performance Monitoring

NCS 2000

Enable this check box to add the Performance Monitoring feature to the license package.

Circuit Provisioning

NCS 2000

Enable this check box to add the Circuit Provisioning feature to the license package.

Step 6

Click Update.


Add Contentionless Side to a Site

Contentionless functionality on a site refers to the contentionless add or drop ability of an N-degree ROADM node to accommodate N wavelengths of the same frequency from a single add or drop device. For a ROADM to be contentionless, the number of drop units must be equal to ROADM degrees.

Use the following procedure to add contentionless sides to a ROADM or traffic site.

Before you begin

Log in to Cisco ONP Web Interface.

Procedure


Step 1

Choose File > Open.

The Select Network To Open dialog box appears.

Step 2

Click the network in which you want to add contentionless sides to a site.

The network opens.

Step 3

Choose Network > Entity Editor.

Step 4

Click the site to which you want to add contentionless sides.

Step 5

Click the Add Contentionless Side icon.

Step 6

Enter the appropriate value in the Enter number of contentionless sides field.

The number of contentionless sides that can be added to a site depends on the type of site, the Scalable Upto Degree property. The following table explains the same.

Table 3. Contentionless Sides for Layer-1 SMR

Site Type

Scalable Upto Degree

Number of Contentionless Sides

SMR-20

4

16

SMR-20

8

12

SMR-20

12

8

SMR-20

16

4

SMR-20

Line

8

SMR-20

Terminal

8

SMR-9

4

5

SMR-9

8

1

Step 7

To add layer-2 SMR-20 contentionless sides, perform the following steps:

  1. Check the Evolved Mesh check box.

  2. Choose Site Type as SMR-20 or Auto.

  3. Check the Cascaded SMR check box.

  4. Choose Degree Mesh Type as DEG-5/UPG-4.

  5. Click Update.

You can add 20 more contentionless sides on each site for layer-2 SMR.

Step 8

Click OK.


Modify Number of Contentionless Side Ports for a Site

Use this task to modify the number of contentionless ports for a side in a ROADM site.

Before you begin
Log in to Cisco ONP Web Interface.
Procedure

Step 1

Choose File > Open.

The Select Network To Open dialog box appears.

Step 2

Click the network in which you want to modify the number of contentionless ports for a side in a ROADM site.

The network opens.

Step 3

Choose Network > Entity Editor.

Step 4

Expand a ROADM site and select a contentionless side.

You can view the properties of the side in the right panel.

Step 5

From the Contentionless Ports drop-down list, choose the required number of ports.

Click Update.


Add L-Band Side to a Site

Use the following procedure to add L-Band sides to an NCS 1010 R7.9.1 site:

Before you begin

Log in to Cisco ONP Web Interface.

Procedure


Step 1

Choose File > Open.

The Select Network To Open dialog box appears.

Step 2

Click the network in which you want to add the L-Band sides to a site.

The network opens.

Step 3

Choose Network > Entity Editor.

Step 4

To add the L-Band sides, choose one of the following options:

  • Click the site to which you want to add the L-Band sides.

    Note

     

    If you add an L-Band side to a site, the corresponding attached sides from other sites also automatically add L-Band sides. An pop-up message appears to indicate the addition of L-Band sides.

  • Or, expand the site and click on a side to add L-Band to the selected side only.

Step 5

Click the Add L-Band icon.

The L-Band side appears under the required site or side.

Note

 

If ILA or pass-through sites are present in APC domain, then the end-to-end path in the L-band becomes enabled automatically.


Modify Fiber Properties

Use this task to modify the properties of fiber.

Before you begin

Log in to Cisco ONP Web Interface

Procedure


Step 1

In the network tree, expand Fiber, and click a fiber.

You can view the basic properties of the fiber at the bottom of the network tree.

Step 2

Modify the following fiber properties as required.

Property Platform Description

General

Name

NCS 2000

NCS 1010

By default, the name of the fiber is based on the number of fibers between the source and destination sites. You can edit the name.

Source

NCS 2000

NCS 1010

Displays the source site name. This field is noneditable.

Destination

NCS 2000

NCS 1010

Displays the destination site name. This field is noneditable.

Bidirectional

NCS 2000

NCS 1010

Indicates whether standard single fiber is used to transmit the data in both directions.

Fiber Type

NCS 2000

Select the fiber type. Cisco ONP supports the following fibers, and the default fiber type is G652-SMF.

  • G652-SMF-28E

  • TWR

  • MC

  • TWPlus

  • TWMinus

  • TWClassic

  • FL

  • TL

  • G652-SMF

  • ELEAF

  • True wave

NCS 1010

Select the fiber type. Cisco ONP supports the following fibers, and the default fiber type is G652-SMF.

  • G652-SMF-28E

  • TWR

  • MC

  • TWPlus

  • TWMinus

  • FL

  • TL

  • G652-SMF

  • ELEAF

  • True wave

Length

NCS 2000

NCS 1010

Displays the span length of the fiber connecting a source and destination site. If necessary, change the span length manually.

  • The Cisco ONP tool automatically updates the fiber length to 1 km or 1 mile. If you change the fiber length, then the tool updates the same in the network tree and the map accordingly.

  • In the network tree pane, expand Fiber and select the fiber couple, A-Z and Z-A. The properties pane displays the fiber couple name, source side, destination side, its span length, loss, and, Polarization Mode Dispersion (PMD) value.

  • You can enter the different span length and loss values for the individual fibers in a fiber couple.

Network status

NCS 2000

NCS 1010

Displays the status of the network, whether the network is being deployed or not. If the network is not deployed, it shows the status as UNDISCOVERED.

Business status

NCS 2000

NCS 1010

Displays the status of the fiber in a business perspective view. If fiber is not deployed, it shows the status as FUTURE. This field is noneditable.

Measurement Units

NCS 2000

NCS 1010

Choose the measurement unit (Km or Miles) for the fiber span. You can set the measurement unit only for the duct, but not for the fiber pair (couple) or fiber.

Aging Loss [dB]

NCS 2000

NCS 1010

Enter the aging loss value for the fiber.

DCN Extension

NCS 2000

NCS 1010

Check this check box to enable the default use of data connection network (DCN) extension on each span in the project. This setting implies that the optical service channel (OSC) channel is not used to connect the two nodes.

OSC FrameType

NCS 2000

Choose the OSC frame type. The options available are:

  • Auto

  • OC3 Frame

  • GE Frame

  • FE Frame

The default option is Auto. When set in Auto, Cisco ONP uses FE Frame as the preferred frame type.

Aging Factor

NCS 2000

NCS 1010

Enter the number to fiber aging factor.

Physical

Length-Based Loss

NCS 2000

NCS 1010

The fiber loss value is automatically calculated based on length and loss coefficient, when you check this option.

Tot SOL Loss w/o connectors

NCS 2000

NCS 1010

Enter the start of life fiber loss value for each span, excluding the connector concentrated loss.

Raman Amplification

Raman Amplified

NCS 2000

Enable Raman Amplification on the ducts.

Note

 
When you enable Raman amplification for NCS 2000 system release 12.2, the side property Enable C+L Band S/C is automatically disabled and vice versa.

Step 3

Click Update.

Step 4

To modify advanced properties of the fibers, click Show Advanced Properties, or choose Network > Entity Editor.

Step 5

Click the FIBER tab in the Entity Editor window.

Step 6

Choose the fiber and modify the following properties in the right pane.

Property

Platform

Description

General

Aging loss

NCS 2000

NCS 1010

Enter the aging loss value.

DCN Extension

NCS 2000

NCS 1010

Enable the default use of data connection network (DCN) extension on each span in the network.

OSC Frame Type

NCS 2000

NCS 1010

Choose the OSC frame type. The options available are Auto, OC3 Frame, Gigabit Ethernet Frame, and Fast Ethernet Frame. The default option is Auto. When set in Auto, Cisco ONP uses Fast Ethernet Frame as the preferred frame type.

Aging Factor

NCS 2000

NCS 1010

Enter the number to factor fiber aging. This factor is multiplied by the SOL total span loss without connectors.

Physical

Connector Loss A

NCS 2000

NCS 1010

Connector Loss at Source Site [dB]

Connector Loss B

NCS 2000

NCS 1010

Connector Loss at Destination Site [dB]

Factors

Loss Coefficient [dB/km]

NCS 2000

NCS 1010

Loss is calculated based on the loss coefficient.

PMD Coeffocient

NCS 2000

NCS 1010

Displays the PMD coefficient.

QD C-Band

NCS 2000

NCS 1010

Displays the secondary order dispersion for C-band.

CD C-Band

NCS 2000

NCS 1010

Displays the secondary order dispersion for L-band.

RD Factor

NCS 2000

NCS 1010

Displays the random dispersion value.

Extended

Effective Mode Area

NCS 2000

NCS 1010

Displays the effective mode area [µm^2]

SRS tilt coefficient

NCS 2000

NCS 1010

Displays the Stimulated Raman Scattering tilt coefficient on the band.

DRBS coefficient

NCS 2000

NCS 1010

Displays the Rayleigh Scattering capture coefficient.

N2

NCS 2000

NCS 1010

Nonlinear index of refraction [1e-16 cm^2/W]

LFBR

NCS 2000

NCS 1010

Length of individual fibers for sigmaDSP [Km]

Totals

(The properties under Totals are noneditable)

Loss EOL

NCS 2000

NCS 1010

Displays the total loss EOL calculation.

Loss SOL

NCS 2000

NCS 1010

Displays the total loss SOL calculation.

CD C-Band

NCS 2000

NCS 1010

Displays the total chromatic dispersion for the C-band.

QD C-Band

NCS 2000

NCS 1010

Displays the secondary order dispersion for C-band.

RD

NCS 2000

NCS 1010

Displays the random dispersion value.

PMD

NCS 2000

NCS 1010

Displays the Polarization Mode Dispersion (PMD) value.

Step 7

Click Update.


Modify Fiber Couple Properties

Use this task to modify properties of the fiber couple.

Before you begin

Log in to Cisco ONP Web Interface.

Procedure


Step 1

In the network tree, expand Fiber, and drill down up to a fiber couple and click the fiber couple.

You can view the basic properties of the fiber couple at the bottom of the network tree.

Step 2

Modify the following fiber couple properties as required.

Property

Platform

Description

General

Name

  • NCS 2000

  • NCS 1010

By default, fiber couple is named based on the fiber name followed by COUPLE-AZ or COUPLE-ZA. The sides that are connected by the fiber couple are indicated inside brackets. The name is noneditable.

Source Side

  • NCS 2000

  • NCS 1010

Displays the source side name. This field is noneditable.

Destination Side

  • NCS 2000

  • NCS 1010

Displays the destination side name. This field is noneditable.

Length

  • NCS 2000

  • NCS 1010

Automatically displays the span length of the fiber connecting a source and destination side. Change the span length manually, if necessary.

You can enter the different span length and loss values for the individual fibers in a fiber couple.

Factors

Loss coefficient [dB]

  • NCS 2000

  • NCS 1010

Enter the value of the SOL fiber loss per kilometer used to calculate the loss of each span in the network.

Totals

Loss SOL

  • NCS 2000

  • NCS 1010

Displays the total loss SOL calculation.

Loss EOL

  • NCS 2000

  • NCS 1010

Displays the total loss EOL calculation.

Physical

Tot SOL Loss w/o connectors

  • NCS 2000

  • NCS 1010

Enter the start of life fiber loss value for each span, excluding the connector concentrated loss.

Step 3

Click Update.

Step 4

To modify advanced properties of the fiber couple, click Show Advanced Properties, or choose Network > Entity Editor.

Step 5

Click the FIBER tab in the Entity Editor window.

Step 6

Choose the fiber and drill down to the fiber couple, and modify the following properties in the right pane.

Property

Platform

Description

Physical

Connector Loss A

  • NCS 2000

  • NCS 1010

Connector Loss at Source Site [dB]

Connector Loss B

  • NCS 2000

  • NCS 1010

Connector Loss at Destination Site [dB]

Factors

PMD coefficient

  • NCS 2000

  • NCS 1010

Displays the PMD coefficient.

Totals

(The properties under Totals are noneditable)
PMD
  • NCS 2000

  • NCS 1010

Displays the PMD value.

Loss EOL

  • NCS 2000

  • NCS 1010

Displays the total loss EOL calculation.

Loss SOL

  • NCS 2000

  • NCS 1010

Displays the total loss SOL calculation.

CD C-Band

  • NCS 2000

  • NCS 1010

Displays the total chromatic dispersion for the C-band.

QD C-Band

  • NCS 2000

  • NCS 1010

Displays the secondary order dispersion for C-band.

RD

  • NCS 2000

  • NCS 1010

Displays the random dispersion value.

Step 7

Click Update.


Modify Service Properties

Use this task to modify the properties of the service.

Before you begin

Log in to Cisco ONP Web Interface.

Procedure


Step 1

In the network tree, expand Services and click a service.

You can view the basic properties of the service at the bottom of the network tree.

Step 2

Modify the following service properties as required.

Property

Platform

Description

General

Name

NCS 2000

By default, the service name is based on the source and destination sites and the number of services between them. You can edit the name.

For example, if there are two services between site 1 and site 2, the names of the services are Site-1-Site-2-1 and Site-1-Site-2-2, respectively.

Type

NCS 2000

Choose the types of service.

Protection

NCS 2000

Choose the protection type from the drop-down list. Options available are:

  • Unprotected

  • 1+1

  • Disjoint

  • S+NS

  • 1+R

  • 1+1+R

  • 1+1+R+R

For more information on protection types, see Supported Protection Schemes.

Source

NCS 2000

Displays the source site name.

Destination

NCS 2000

Displays the destination site name.

Step 3

Click Update.

Step 4

To modify advanced properties of the service, click Show Advanced Properties or choose Network > Entity Editor.

Step 5

In the Entity Editor window, click the Service tab.

Step 6

Choose the service under the network tree, and modify the following properties in the right pane.

Property

Platform

Description

General

Tertiary Source

NCS 2000

From the drop-down list, select the possible site as a tertiary source.

Tertiary Destination

NCS 2000

From the drop-down list, select the possible site as a tertiary destination.

Tertiary source and tertiary destination are enabled only when you select the protection scheme as Unprotected Disjoint.

You can select either tertiary destination or both tertiary source and tertiary destination.

  • If you select only the tertiary destination, the demand is created between the source and destination and between the source and tertiary destination. These do not have common fibers in the path, which are disjoint.

  • If you select both tertiary source and tertiary destination, two unprotected demands are created between the source to destination, and tertiary source to tertiary destination. The demands are disjoint to each other.

Primary Path Forcing

Path

NCS 2000

Cisco ONP automatically selects the shortest path as working path and also allows you to force the path manually.

Fiber

NCS 2000

Primary path fiber is forcing path for working trail.

Regeneration Platform

NCS 2000

Displays the platform of the regeneration site

Regen Sites

NCS 2000

Choose the regeneration site.

Wavelength

NCS 2000

Click Edit to choose the wavelength. The default option is Auto.

ODU Timeslot

NCS 2000

Enter the ODU timeslot value.

Section Wavelength(s)

NCS 2000

Displays the selected Wavelength.

Src Channel Type

NCS 2000

Choose the type of source channel. The available options are:

  • Auto—This is the default option. Auto option is the contentionless demand.

  • Contentionless

  • Colorless

  • Colored

Dst Channel Type

NCS 2000

Choose the type of destination channel.

Secondary Path Forcing (Available only for (1+1)

Path

NCS 2000

Secondary path is the protected path when the primary path fails. This path is the second best path after the primary path.

Fiber

NCS 2000

Secondary path fiber is for protected service, forcing path for the protected trail.

Regeneration Platform

NCS 2000

Displays the platform of the regeneration site

Regen Sites

NCS 2000

Choose the regeneration site.

Wavelength

NCS 2000

Click Edit to choose the wavelength. The default option is Auto.

ODU Timeslot

NCS 2000

Enter the ODU timeslot value.

Section Wavelength(s)

NCS 2000

Displays the selected Wavelength.

Src Channel Type

NCS 2000

Choose the type of source channel.

Dst Channel Type

NCS 2000

Choose the type of destination channel.

Restoration 1 Path Forcing (Available for 1+R, 1+1+R, 1+1+R+R)

Path

NCS 2000

Cisco ONP automatically selects the first restoration path.

Fiber

NCS 2000

Choose the first restoration path fibers.

Restoration 2 Path Forcing (Available for 1+1+R+R)

Path

NCS 2000

Cisco ONP automatically selects the second restoration path.

Fiber

NCS 2000

Choose the second restoration path fibers.

NCS 1 K Domain

Client Type

NCS 2000

Displays the client type. By default, client type is OTU4.

Interface Type

NCS 2000

Displays the interface type. By default, interface type is BH.

Trunk Mode

NCS 2000

Choose whether the trunk mode is 200G or 300G. By default, Trunk Mode is 200G.

Note

 

Based on the selected trunk mode, Baud rates are filtered.

Baud Rate

NCS 2000

Choose whether the Baud rates mode as 60 or 69GBd.

Note

 
  • Ensure that you force both primary and secondary path fiber or channel for protected service. Also ensure that the wave type is same for both primary and secondary paths. While doing path forcing, make sure that you perform an end-to-end path forcing from the source to the destination. Analysis fails if the partial path is forced.

  • Force the wave path for the wave, which is tagged to the service.

  • In case of protection type: 1+1+R+R, 1+1+R, and 1+R, you can force a path in restoration path1 or restoration path2 Fiber that is forced in primary or secondary path Fiber.

Step 7

Click Update.


Services Aggregation

Table 4. Feature History

Feature Name

Release Information

Feature Description

Services Aggregation

Cisco ONP Release 4.1

Services aggregation feature allows two or more services to share the same trunk port or channel. By default, the services are added to the DefaultGroup. You can also export the aggregation reports.

Services aggregation indicates whether two or more services can share the same trunk port or channel. The aggregation is defined based on the properties of the Service Group. When you add services to the Traffic site (of the type 1K-2K-4K) in an SSON network, a DefaultGroup is created under the Services in the network tree. The services that you add, are associated to the DefaultGroup.

Create a New Service Group

Use this task to create a new service group:

Before you begin

Log in to Cisco ONP Web Interface

Procedure


Step 1

Choose File > Open.

The Select Network To Open dialog box appears.

Step 2

Click a network, where you want to create a new service group.

The network opens.

Step 3

Right-click Services under the network tree and choose Create Service Group.

A new service group gets created under the Services.


Modify Service Group Properties

Use this task to modify the properties of service group.

Before you begin

Log in to Cisco ONP Web Interface.

Procedure


Step 1

In the network tree, expand Services and click a service group.

You can view the basic properties of the service at the bottom of the network tree.

Step 2

Modify the following service properties as required.

Property

Platform

Description

General

Name

NCS 2000

By default, the service name is based on the source and destination sites and the number of services between them. You can edit the name.

For example, if there are two services between site 1 and site 2, the name of the services are Site-1-Site-2-1 and Site-1-Site-2-2, respectively.

Demand Types

NCS 2000

Choose the demand type. For default group all demand types are available, and you cannot edit them.

Default Group

NCS 2000

Indicates whether the service group is a default group or a user created group.

NCS 4 K

Exclusive LC Usage

NCS 4000

Indicates whether the services belonging to this group must have an exclusive Line Card (LC) or not.

For example, when you check this check box, neither the Client LC nor the Trunk LC of the services belonging to this group can be shared by services belonging to any other groups.

Symmetric Aggregation

NCS 4000

Indicates whether this group allows aggregation of only symmetric services. Services are symmetric if they have same protection scheme. Following are the various protection schemes:

  • Unprotected

  • 1+R

  • 1+1

  • 1+1+R

  • 1+1+R+R

For Example, all “1+1” services are symmetrical.

If you check this check box, this service group allows aggregation of only symmetrical services.

For example, “Unprotected” can be aggregated only with “Unprotected”, “1+R” only with “1+R”, “1+1” only with “1+1”, and so on.

If this check box is unchecked, this service group allows aggregation of symmetrical and unsymmetrical services together.

For example, “Unprotected” can be aggregated with either “Unprotected”, “1+R”, “1+1” “1+1+R” or “1+1+R+R”.

See Aggregation Rules.

NCS 1 K

Exclusive LC Usage

NCS 1004

Same as NCS 4 K.

Symmetric Aggregation

NCS 1004

Same as NCS 4 K.

Step 3

Click Update.


Aggregation Rules

Following are the rules for any two services (symmetrical or nonsymmetrical) to be aggregated:

  • The services must have the same Source and Destination.

  • The services must have same paths for the same path types.

    For example:

    • For symmetric aggregation between two “1+1” services, the working path of the first service must match with the working path of the second service and the protection path of the first service must match with the protection path of the second service.

    • For non-symmetric aggregation between “1+1” and “1+1+R” services, the working path of the first service must match with the working path of the second service and the protection path of the first service must match with the protection path of the second service. The restoration path of second service can be anything.

  • The services must be configured to use same wavelength for same path types.

  • If the wavelength is set to “auto”, it is flexible to be aggregated with other “auto" wavelength or a fixed wavelength.

  • The services must be configured to use same trunk mode for same path types.

  • The services must be configured to use same regeneration sites for same path types.


Note


Demand Type is not used as a constraint for aggregation (except for trunk capacity availability).


Associate a Service to the Newly Created Group

By default, the services are associated to the DefaultGroup. But you can change the group.

Before you begin

Log in to Cisco ONP Web Interface.

Procedure


Step 1

In the network tree, click the service that you want to associate to a group.

You can view the basic properties of the network at the bottom of the network tree.

Step 2

Choose the group from the Service Group drop-down list.

Step 3

Click Update.

Note

 

For an LNI imported network, by default, all the services are present in the Default group. Only when you upgrade the LNI imported network for the first time, you can move the services to other newly created Service Groups without having to unlock them. On subsequent upgrades, you must unlock the services to facilitate the movement between Service Groups. Also, the Service Groups are in locked state in the upgrade mode, unless a complete Network-level unlock has been performed.


What to do next

Export Aggregation Reports

Use this task to export the service aggregation reports:

Before you begin

Log in to Cisco ONP Web Interface.

Procedure


Step 1

Choose File > Open.

The Select Network To Open dialog box appears.

Step 2

Click an analyzed network.

The network opens.

Step 3

Choose Export > Service Aggregation.

Step 4

Save the aggregation report in the form of an Excel sheet to your local system.


Modify Wave Properties

Use the following task to modify the properties of the wave.

Before you begin

Log in to Cisco ONP Web Interface.

Procedure


Step 1

In the network tree, expand Waves, and click a wave.

You can view the basic properties of the wave at the bottom of the network tree.

Step 2

Modify the following wave properties as required.

Property

Platform

Description

General

Label

NCS 2000

By default, the wave is named based on the source and destination sites and the number of waves between them. You can edit the name.

For example, if there are two waves defined between site 1 and site 2, the waves are named as Site-1-Site-2-1 and Site-1-Site-2-2, respectively.

Source Site

NCS 2000

Displays the source site name.

Destination Site

NCS 2000

Displays the destination site name.

Traffic Type

NCS 2000

Choose the traffic type from the drop-down list. The available options are:

  • Optical Source

  • 100GE

  • 10GE LAN PHY

  • 40GE LAN PHY

  • Fiber Channel 10G

  • Fiber Channel 16G

  • Fiber Channel 8G

  • OC-192/STM-64

  • OTU2

  • OTU2e

  • OTU4

  • Pluggable Card

Protection Type

NCS 2000

Choose the protection type.

  • Unprotected

  • Client 1+1

For more information on protection types, see Supported Protection Schemes.

Forecast

NCS 2000

Check this check box to change a present wave to a forecast wave.

Encryption

NCS 2000

Check this check box to enable encryption.

Step 3

Click Update.


Modify Media Channel Properties

Use the following task to modify properties of the media channel.

Before you begin

Log in to Cisco ONP Web Interface.

Procedure


Step 1

In the network tree, expand Media Channels, and click a media channel.

You can view the basic properties of the media channel at the bottom of the network tree.

Alternatively, you can choose Network > Entity Editor > Services, expand Media Channels, and click a media channel to view the properties.

Step 2

Modify the following properties as required.

Property

Platform

Description

General

Label

NCS 2000

By default, the media channel is named based on the source and destination sites and the number of media channels between them. You can edit the name.

For example, if there are two media channels between site 1 and site 2, they are named as Site-1-Site-2-1 and Site-1-Site-2-2, respectively.

Source Site

NCS 2000

Displays the source site name.

Destination Site

NCS 2000

Displays the destination site name.

Traffic Type

NCS 2000

Choose the traffic type from the drop-down list. The available options are:

  • Optical Source

  • 100GE

  • 10GE LAN PHY

  • 40GE LAN PHY

  • Fiber Channel 10G

  • Fiber Channel 16G

  • Fiber Channel 8G

  • OC-192/STM-64

  • OTU2

  • OTU2e

  • OTU4

  • Pluggable Card

Protection Type

NCS 2000

Choose the protection type.

  • Unprotected

  • Client 1+1

For more information on protection types, see Supported Protection Schemes.

For Client 1+1, ensure that the sites have contentionless sides for the analysis to be successful. By default, Cisco ONP finds both span and node disjoint path for Client1+1 protected waves, but allows you to force span and node disjoint path.

Forecast

NCS 2000

Check this check box to change a present wave to a forecast wave.

Encryption

NCS 2000

Check this check box to enable encryption.

Step 3

Click Update.


Modify Circuit Properties

Use the following task to modify the properties of the circuit in an NCS 1010 network.

Before you begin

Log in to Cisco ONP Web Interface.

Procedure


Step 1

In the network tree, expand Circuits, and click a circuit.

You can view the basic properties of the circuit at the bottom of the network tree.

Step 2

Modify the following circuit properties as required.

Property

Platform

Description

General

Label

NCS 1010

By default, the circuit is named based on the source and destination sites and the number of circuits between them. You can edit the name.

For example, if there are two circuits defined between site 1 and site 2, the circuits are named as Site-1-Site-2-1 and Site-1-Site-2-2, respectively.

Source Site

NCS 1010

Displays the source site name.

Destination Site

NCS 1010

Displays the destination site name.

Traffic Type

NCS 1010

Choose the traffic type from the drop-down list. The available options are:

  • Optical Source

  • Pluggable Card

Note

 

QDD interfaces (both as optical source and pluggable) are not supported with colorless BRK-8, BRK-16, and BRK-24 configurations.

Protection Type

NCS 1010

Choose the protection type. Currently, we support only Unprotected.

Step 3

Click Update.


Modify Trail Properties

Use this task to modify the properties of the trail.
Table 5. Feature History

Feature Name

Release Information

Description

Bright ZR+ Pluggable Support

Cisco ONP Release 5.1

The Bright ZR+ pluggable can now be included in the network design by choosing them as Card Type or Client Interface under the Trail properties. This selection is available for all types of sites. The Bright ZR+ pluggable has high transmit optical power up to 0dBm, high transmit OSNR, and high-density QSFP-DD form factor.

Table 6. Feature History

Feature Name

Release Information

Description

Multilayer Nodes Enhancements

Cisco ONP Release 5.1

You can now choose from the full array of supported Card Types and Client Interfaces under the Trail properties option for the multilayer nodes. Previously, only a limited set of cards were available for selection. With this enhancement, you can design diverse networks leveraging the unique functionalities of all types of cards.

Before you begin

Log in to Cisco ONP Web Interface.

Procedure


Step 1

In the network tree, expand Waves, Media Channels or Circuits, drill down up to trail and click a trail.

The basic properties of the trail are displayed at the bottom of the network tree.

Step 2

Modify the following trail properties as required.

Property

Platform

Description

General

Label

NCS 2000

NCS 1010

Displays the name of the trail.

Path of Wave

NCS 2000

NCS 1010

Select a fiber from the drop-down list.

Regen Sites

NCS 2000

NCS 1010

Select the regeneration site.

Source Site

NCS 2000

NCS 1010

Displays the source site name.

Destination Site

NCS 2000

NCS 1010

Displays the destination site name.

Wavelength

NCS 2000 (Non-SSON)

Click Edit to choose the wavelength. The default option is Auto.

Central Wavelength [nm]

NCS 2000

NCS 1010

Click Edit to choose the central wavelength. The default option is Auto.

Note

 

If you select L-Band as Band Type, the L-band wavelength options appear along with C-band wavelengths for NCS 1010 R7.9.1.

Multicarrier

NCS 2000

NCS 1010

Indicates whether the transmission is a multicarrier transmission.

Trunk Mode

NCS 2000

NCS 1010

The trunk mode can be edited only when you choose 400G-XP-LC as Card Type.

Step 3

To modify the advanced properties of the trail, click Show Advanced Properties or choose Network > Entity Editor.

Step 4

In the Entity Editor window, click the Service tab.

Step 5

Expand Waves, Media Channels or Circuits, under the network tree, drill down to the trail, click the trail, and modify the following properties that are displayed in the right pane.

Property

Platform

Description

General

OSNR Forward [dB]

NCS 2000 (non-SSON)

Displays the forward optical signal to noise ratio.

OSNR Reverse [dB]

NCS 2000 (non-SSON)

Displays the reverse optical signal to noise ratio.

Band Type

NCS 1010

Choose the required band type for the circuit.

Note

 

When you select L-Band as Band Type, then the Add/Drop Type field automatically selects Colorless and becomes disabled.

Filtering Penality

NCS 2000

NCS 1010

Displays the value of the penalties that are caused by the different filter types (OADM, and ROADM).

OTN (non-SSON)

ODUTimeslot

NCS 2000 (non-SSON)

Displays the Optical Data Unit timeslot.

SRLGs

NCS 2000 (non-SSON)

Displays the SRLGs associated with the trail.

OTN Hops

NCS 2000 (non-SSON)

Displays the number of OTN hops.

Quantity

NCS 2000 (non-SSON)

Displays the number of OTN services on the trail.

Source

Card Type

NCS 2000

NCS 1010

Choose the card used in the source site. See Supported Cards and Pluggables and Supported Optical Sources for more information on the list of supported cards.

From Release 5.1, Bright ZR+ pluggables are supported for all the type of sites. Also, there are no limitations on the type of cards that can be chosen for the multilayer nodes.

Note

 
  • Non-SSON

    • Colored and colorless—Baud rates less than 42 are supported and listed.

    • Contentionless—Mean power less than –4.4 is supported and listed.

  • SSON

    • Colored—Baud rates less than 65 are supported and listed.

    • Colorless—All interfaces supported and listed.

    • Contentionless—Mean power less than –4.4 are supported and listed.

Mean power = (ochData.txRange.max + ochData.txRange.min)/2

If contentionless is selected for the source channel type, the QDD interfaces are not supported.

Client Interface

NCS 2000

NCS 1010

Choose the pluggable from the drop-down list. The pluggables suitable for the chosen card type are displayed.

See Supported Cards and Pluggables for more information on the list of supported pluggables.

From Release 5.1, Bright ZR+ pluggables are supported for all the type of sites. Also, there are no limitations on the type of cards that can be chosen for the multilayer nodes.

The pluggable FR-1(QSFP-100G-FR-S) is supported on the client ports of the 400G-XP LC starting from NCS 2000 Release 11.1.0.

The pluggable ERL (QSFP-100G-ERL-S) is supported on the client ports of the 400G-XP LC with 100GE traffic type starting from NCS 2000 Release 11.1.3.

Note

 

When you export the NCS 2000 R11.1.3 network, the Cisco ONP exports the NCS 2000 R11.1.0 report. You must edit the exported report for R11.1.3.

Add/Drop Type

NCS 2000

Choose the type of Add/Drop. The available options are:

  • Auto

  • Contentionless

  • Colorless

  • Colored

NCS 1010

Choose the type of Add/Drop. The available options are:

  • Auto

  • Colorless

  • Colored

Trunk Type

NCS 2000

NCS 1010

Choose the trunk type from the drop-down list.

Contentionless Side

NCS 2000

Choose the contentionless side from the drop-down list.

Destination

Card Type

NCS 2000

NCS 1010

The destination card type is auto populated based on the source card type chosen.

Client Interface

NCS 2000

NCS 1010

Choose the pluggable from the drop-down list. The pluggables suitable for the chosen card type are displayed.

Trunk Type

NCS 2000

NCS 1010

Choose the trunk type from the drop-down list.

Add/Drop Type

NCS 2000

Choose the type of the Add/Drop. The available options are:

  • Auto

  • Contentionless

  • Colorless

  • Colored

NCS 1010

Choose the type of the Add/Drop. The available options are:

  • Auto

  • Colorless

  • Colored

Contentionless Side

NCS 2000

Choose the contentionless side from the drop-down list.

Step 6

Click Update.


Modify Section Properties

Use this task to modify properties of the section.

Before you begin

Log in to Cisco ONP Web Interface.

Procedure


Step 1

In the network tree, expand Waves, drill down up to section and click a section.

You can view the basic properties of the section at the bottom of the network tree.

Step 2

Modify the section properties as required.

Section and trail have the same properties. Refer Modify Trail Properties for the descriptions of the properties.

Step 3

Click Update.


Modify Side Properties

Table 7. Feature History

Feature Name

Release Information

Feature Description

Support for NCS2K-MF-CL-SC (C and L-band combiner and splitter)

Cisco ONP Release 4.2

Cisco ONP supports the passive module, NCS2K-MF-CL-SC (C and L-band combiner and splitter), starting from the NCS 2000 system release 12.2 for SSON and non-SSON networks. This feature enables combining C and L band wavelengths.

Table 8. Feature History

Feature Name

Release Information

Feature Description

NCS2K-RMN-CTP-C+L support

Cisco ONP Release 5.0

Cisco ONP now supports the passive module, NCS2K-RMN-CTP-C+L (C- and L-band counterpropagating Raman amplifier), starting from the NCS 2000 system release 12.3.1 for SSON and non-SSON networks.

Use this task to modify the properties of a side in a site.

Before you begin

Log in to Cisco ONP Web Interface.

Procedure


Step 1

In the network tree, Choose Sites > Site > Site domain > Side.

Step 2

To modify the side properties, perform the following steps:

  1. Click Show Advanced Properties.

  2. In the right pane of Entity Editor window, modify the following properties of the side.

    Note

     

    You cannot edit the properties of the Pass through site side.

    Options

    Platform

    Description

    General

    Label

    NCS 2000

    NCS 1010

    Displays the label of the side.

    Note

     

    For L-band nodes, the suffix L is added to the side label.

    Type

    NCS 2000

    NCS 1010

    Displays the type of the side. You cannot edit this property.

    Node Address

    NCS 1010

    Enter the node address

    MPO Cable

    NCS 1010

    Choose the MPO cable. The available options are:

    • Auto

    • 16MPO-MPO

    • 24MPO-MPO

    Colorless Ports (Displayed for Line side)

    NCS 2000

    Enter the number of colorless ports.

    Contentionless Ports (Displayed for Contentionless side)

    NCS 2000

    Choose the number of contentionless ports.

    Enable C+L Band S/C (Displayed for Line side type)

    NCS 2000

    Cisco ONP supports the following passive modules:

    • NCS2K-MF-CL-SC (C and L-band combiner and splitter), starting from the NCS 2000 system release 12.2 for SSON and non-SSON networks. Check this check box to enable the NCS2K-MF-CL-SC card. This card is supported for ROADM, OLA, and traffic nodes, but not on the passthrough node.

      Note

       

      When you enable this option on a side:

      • It is automatically enabled on the side that is connected to the selected side through a fiber.

      • The fiber property Raman Amplified is automatically disabled, and the opposite way.

      • This card introduces a certain amount of attenuation and insertion loss that is reflected in the ANS parameters.

      The NCS2K-MF-CL-SC module does not appear in the layout.

    • NCS2K-RMN-CTP-C+L (C- and L-band counterpropagating Raman amplifier), starting from the NCS 2000 system release 12.3 for SSON and non-SSON networks. Check this check box to enable the NCS2K-RMN-CTP-C+L card.

      Note

       

      When you enable this option on a side:

      • If you enable the fiber property Raman Amplified, then the NCS2K-RMN-CTP-C+L card is automatically forced.

      • If you disable the fiber property Raman Amplified, then the NCS2K-MF-CL- SC card is automatically forced.

      • Fiber property Raman Amplified is automatically disabled for NCS 2000 system release 12.2.

      The NCS2K-RMN-CTP-C+L module appears in the layout.

    Band Type

    NCS 1010

    Choose the required band type.

    The available options are:

    • C-Band

    • C+L Futuristic

    Bill of Material

    License Suite

    NCS 1010

    Choose whether the License Suite is Essential (RTU +SIA3) or Advanced (RTU +SIA3).

    Layout

    Power Supply

    NCS 1010

    Choose the type of Power Supply. The available options are Auto, AC Power, and DC Power.

    The default option is Auto.

    With Auto option, default power supply is selected as DC Power.

    Controller Card

    NCS 1010

    Choose the type of the controller card. The available options are:

    • Auto

    • NCS1010-CNTRL-K9

    Redundant Controller Card

    NCS 1010

    Displays the redundant controller card, if any. Else displays No.

    UTS AC Power Cables

    NCS 1010

    Choose the type of cables to be used for the AC power supply. You can choose the cables when the Power Supply is set as AC Power or DC Power.

    Redundant Power Scheme

    NCS 1010

    Choose the redundant power scheme from the drop-down list to configure the number of working and protected power units for the chassis. The available options are Auto, 1+0, and 1+1.

    MF Unit

    NCS 1010

    Choose the mechanical frame for the passive optical modules from the drop-down list. The options available are Auto, MF-1RU, and MF-4RU.

  3. Click Update.


Modify C-Band Amplifier Properties

Table 9. Feature History

Feature Name

Release Information

Feature Description

Manual Editing of Raman COP values

Cisco ONP Release 4.1

This feature allows you to edit the crosstalk values of the Raman COP amplifier in the SSON network, starting from NCS 2000 Release 11.1.

Table 10. Feature History

Feature Name

Release Information

Feature Description

Inline Amplifier

Cisco ONP Release 4.2

The Inline Amplifier option allows you to enable an inline amplifier in the network. You can simulate the optical feasibility of the network with and without an inline amplifier. Based on the colorless or colored add/drop type selected and the QSFP-DD pluggable status, a default inline amplifier is enabled for the network.

Use this task to modify the properties of a c-band amplifier in a site.


Note


Make sure that SMR card is forced on the site before you update the c-band amplifier properties.


Before you begin

Log in to Cisco ONP Web Interface

Procedure


Step 1

In the network tree, choose Sites > Site > Site domain > Side > C-Band.

Step 2

To modify the amplifier properties, perform the following steps:

  1. Click C-Band Amplifier.

    You can view the properties of the C-Band Amplifier at the bottom of the network tree. For more information, see Supported Amplifiers.

  2. Modify the following properties of the amplifier:

    You can also modify the properties by choosing the C-Band Amplifier under Network > Entity Editor.

    Options

    Platform

    Description

    General

    PSD Shape

    NCS 1010

    Enter a Power Spectral Density (PSD) value.

    Dual Band PSD Shape

    NCS 1010

    Enter Central PSD and Tilt values.

    Raman COP Tilt

    NCS 2000

    The default value is Auto. You can enter a value.

    Pre Tilt

    NCS 2000

    NCS 1010

    The default value is Auto. You can enter a value.

    Raman Tilt

    NCS 2000

    NCS 1010

    The default value is Auto. You can enter a value.

    Booster Tilt

    NCS 2000

    NCS 1010

    The default value is Auto. You can enter a value.

    Inline Amplifier

    NCS 2000

    Choose whether inline amplifier can be forced. The available options are:

    • Yes―EDFA17 or EDFA35 amplifier is chosen as the default amplifier when you choose colored add/drop module MD-64-C or colorless add/drop MF-6AD-CFS, respectively. See Modify Add/Drop Multiplexer Properties.

    • No―No amplifier can be forced.

    • Auto

      • EDFA17 amplifier is chosen as the default amplifier when any one of the demands aggregated in MD-64-C has low launch power optical resource or QSFP-DD pluggable is forced.

      • EDFA35 amplifier is chosen as the default amplifier when any one of the demands aggregated in MF-6AD-CFS has low launch power optical resource or QSFP-DD pluggable is forced.

    Note

     

    When you configure MF-6AD-CFS+EDFA35 in an SSON or non-SSON network, the optical results show system error for the demands of the same or different types. This error affects the what-if analysis. Hence we recommend choosing the appropriate channel and client attenuators so that the inline amplifier works at the proper gain range.

    You can view the amplifier added in the IPC, BOM, and Layout tabs, after the successful analysis.

    Note

     
    • When you add a QDD demand while upgrading a network where the Inline Amplifier property is set as no, the inline amplifier can be included in the network only if you unlock the side and set the Inline amplifier property as Auto or Yes.

    • Default colorless configuration does not require inline amplifier.

    • When there are no demands passing through the colored or colorless Add/Drop device, the forced Inline amplifier is not placed.

    From Fiber

    Pre Amp

    NCS 2000

    Choose a preamplifier from the drop-down list. The default value is Auto. To enable this field for ROADM and Traffic nodes, you must choose SMR-9 or SMR-20 from the Site Type drop-down list under the Site properties.

    If you choose SMR-9, the available options are:

    • SMR9-FS-EDFA17-PRE

    • SMR9-FS-EDFA24-PRE

    • SMR9-FS-EDFA24-PRE

    If you choose SMR-20, the available options are:

    • SMR20-FS-EDFA17-PRE

    • SMR20-FS-EDFA24-PRE

    For the OLA site, the available options are:

    • EDFA35-35-PRE

    • EDFA35-24-PRE

    • OPT -EDFA-17

    • OPT -EDFA-24

    NCS 1010

    The options available for NCS 1010 are:

    • Auto

    • Normal

    • Extended

    Output Power

    NCS 2000

    The default value is Auto. You can enter a value.

    Attenuator In

    NCS 2000

    This field is enabled only when you choose a preamplifier. Choose an attenuator from the drop-down list. The available options are:

    • ATT-LC-2

    • ATT-LC-3

    • ATT-LC-5

    • ATT-LC-7

    • ATT-LC-10

    • ATT-LC-12

    • ATT-LC-15

    • ATT-LC-18

    Attenuator Out

    NCS 2000

    This field is enabled only when you choose a preamplifier. Choose an attenuator from the drop-down list. The available options are:

    • ATT-LC-2

    • ATT-LC-3

    • ATT-LC-5

    • ATT-LC-7

    • ATT-LC-10

    • ATT-LC-12

    • ATT-LC-15

    • ATT-LC-18

    To Fiber

    Booster

    NCS 2000

    The default value is Auto. To enable this field for ROADM and Traffic nodes, you must choose SMR-9 or SMR-20 from the Site Type drop-down list under the Site properties.

    If you choose SMR-20, the default booster is 20SMR-FS-BST.

    If you choose SMR-9, default booster is SMR9-FS-EDFA-BST.

    For the OLA node, the available options are:

    • EDFA35-35-BST

    • EDFA35-24-BST

    • OPT -EDFA-17

    • OPT -EDFA-24

    NCS 1010

    For NCS 1010, it is OLT-C-EDFA-Bst

    Output Power

    NCS 2000

    The default value is Auto. You can enter a value.

    Attenuator In

    NCS 2000

    This field is enabled only when you choose a booster. Choose an attenuator from the drop-down list. The available options are:

    • ATT-LC-2

    • ATT-LC-3

    • ATT-LC-5

    • ATT-LC-7

    • ATT-LC-10

    • ATT-LC-12

    • ATT-LC-15

    • ATT-LC-18

    Attenuator Out

    NCS 2000

    This field is enabled only when you choose a booster. Choose an attenuator from the drop-down list. The available options are:

    • ATT-LC-2

    • ATT-LC-3

    • ATT-LC-5

    • ATT-LC-7

    • ATT-LC-10

    • ATT-LC-12

    • ATT-LC-15

    • ATT-LC-18

    Raman Amplification

    Raman Amp

    NCS 2000

    Choose the Raman amplifier from the drop-down list.

    Note

     

    To force the RAMAN amplifier on NCS 2000 node, you must enable RAMAN amplified on the fiber, else the Raman Amp is disabled, and network analysis fails.

    Note

     

    When you enable the fiber property Raman amplified and the side property Enable C+L Band S/C for NCS 2000 node, Raman Amp is automatically forced as RAMAN-C+L.

    The available options for NCS 2000 ROADM and Traffic sites are:

    • RAMAN-CTP

    • RAMAN-COP-CTP

      Raman Amp can be forced only between two nodes.

    The available options for the OLA site are:

    • EDRA1-26

    • EDRA1-35

    • EDRA2-26

    • EDRA2-35

    • RAMAN-CTP

    NCS 1010

    The available options for NCS 1010 ROADM site are:

    • Auto

    • None

    • Raman

    Note

     

    For NCS 1010 network, when Raman is forced on one side, Raman is automatically forced on all connected sides (APC Domain). If there are passthrough nodes connected, Raman will be automatically enabled on both sides of the passthrough nodes.

    Raman CTP Gain

    NCS 2000

    Enter a value.

    Raman COP Gain

    NCS 2000

    Enter a value. This field is enabled only when you choose RAMAN-COP-CTP.

    Raman Gain

    NCS 1010

    Displays the Raman gain.

    Static Data

    NCS 2000

    By default, this option is disabled. Enable it to edit the crosstalk values of the Raman COP amplifier.

    Note

     

    Static data is supported from Release 11.1 for SSON network.

    Linear XT Avg

    NCS 2000

    Edit the value of average linear crosstalk.

    Linear XT Six

    NCS 2000

    Edit the value average linear crosstalk sigma.

    NonLinear XT Avg

    NCS 2000

    Edit the value of average nonlinear crosstalk.

    NonLinear XT Sig

    NCS 2000

    Edit the value of average nonlinear crosstalk sigma.

    Note

     

    Raman crosstalk values are present in the ANS file under logoparameters section.

  3. Click Update.


Modify L-Band Amplifier Properties

Use this task to modify the properties of an L-band amplifier in a site.

Before you begin

Log in to Cisco ONP Web Interface

Procedure


Step 1

In the network tree, choose Sites > Site > Site domain > Side > L-Band.

Step 2

To modify the amplifier properties, perform the following steps:

  1. Click L-Band Amplifier.

    You can view the properties of the L-Band Amplifier at the bottom of the network tree. For more information, see Supported Amplifiers.

  2. Modify the following properties of the amplifier:

    You can also modify the properties by choosing the L-Band Amplifier under Network > Entity Editor.

    Options

    Platform

    Description

    General

    PSD Shape

    NCS 1010

    Enter a Power Spectral Density (PSD) value.

    Dual Band PSD Shape

    NCS 1010

    Enter Central PSD and Tilt values.

    Pre Tilt

    NCS 1010

    The default value is Auto. You can enter a value.

    Raman Tilt

    NCS 1010

    The default value is Auto. You can enter a value.

    Booster Tilt

    NCS 1010

    The default value is Auto. You can enter a value.

    From Fiber

    Pre Amp

    NCS 1010

    The options available for NCS 1010 are:

    • Normal

    • Extended

    To Fiber

    Booster

    NCS 1010

    For NCS 1010, it is OLT-L-EDFA-Bst

  3. Click Update.


Modify Add/Drop Multiplexer Properties

Table 11. Feature History

Feature Name

Release Information

Feature Description

Modify Properties of Add/Drop Multiplexer and Demultiplexer

Cisco ONP Release 4.2

You can create and validate network designs by choosing colored and colorless add/drop multiplexers and demultiplexers, and interlever under C-Band > Add/Drop. The following options are supported in this release:

Type of Add/Drop Options Network Supported
Colorless
  • Direct SMR

  • MF-6AD-CFS

  • SSON

  • Non-SSON

Colored
  • MD-64-C

  • MD-48-ODD

  • MD-48-EVEN

  • MD-48-ODD + MD-48-EVEN

  • SSON

  • Non-SSON

Interlever

  • MpoCable

  • MD-48-CM

  • Non-SSON

Use this task to modify the properties of the add/drop multiplexer in a site.

Before you begin

Log in to Cisco ONP Web Interface.

Procedure


Step 1

In the network tree, Choose Sites > Site > Site domain > Side > C-Band.

Step 2

To modify the Add/Drop multiplexer card properties, perform the following steps:

  1. Click Add/Drop.

    You can view the properties of the add/drop multiplexer at the bottom of the network tree.
  2. Modify the following properties of the add/drop multiplexer:

    You can also modify the properties by choosing the Add/Drop under Network > Entity Editor.

    Options

    Platform

    Description

    General

    Colored Add/Drop

    NCS 2000

    Choose the colored add/drop multiplexer and demultiplexer: The available options are:

    • MD-64-C―Passive optical multiplexer and demultiplexer module (for SSON network)

    • None

    • Auto

    To mix 16-AD-CCOFS and MD-48-ODD/EVEN on the same MPO port of SMR-20 and connect MD-48-ODD/EVEN to SMR-20 via MPO-8LC and UPG-4, enable Shared SMR port and force the required colored Add/Drop.

    The following options are added automatically based on the colored demands created and the wavelengths forced in the non-SSON network.

    • MD-48-ODD

    • MD-48-EVEN

    • MD-48-ODD + MD-48-EVEN

    NCS 1010

    The options available for NCS 1010 are:

    • Auto

    • None

    • MD-32-EVEN

    • MD-32-ODD

    • MD-32- ODD+MD-32-EVEN

    Colorless Add/Drop

    NCS 2000

    Choose the colorless add/drop multiplexer and demultiplexer: The available options for NCS 2000 are:

    • Auto

    • Direct SMR―SMR-20 card that is directly connected to the colorless channels through MF-MPO-16-LC.

      Note

       

      If the Site Type property is set to SMR-9, the Colorless Ports property under the Side will be disabled.

    • MF-6AD-CFS―6 Port Add/Drop Module (supported only for ROADM starting from NCS 2000 system release 11.0, and traffic site).

      Note

       

      If you choose MF-6AD-CFS for a side, we recommend you to choose the same for other sides of the site.

    NCS 1010

    The options available for NCS 1010 are:

    • Auto

    • None

    • BRK-8

    • BRK-16

    • BRK-24

    Note

     

    QDD optical sources are not supported (both as optical source and pluggable) with colorless BRK-8, BRK-16, or BRK-24 configurations.

    Colorless Ports

    NCS 1010

    Enter the number of colorless ports. The default values is 0. If you do not change the default value, Cisco ONP automatically calculates the number of colorless ports based on the number of circuits added and colorless add/drop units forced.

    Interlever Type

    NCS 2000

    Choose the interlever type from the drop-down list. The available options are:

    • Auto

    • MpoCable

    • MD-48-CM

    Note

     

    Interlever Type property is visible and editable only for Line sides of Multi-Degree nodes having Site Type property as SMR-9 and Scalable Upto Degree property as 8 under the C-Band tab at the Site level.

  3. Click Update.


Modify L-Band Add/Drop Multiplexer Properties

Use this task to modify the properties of the add/drop multiplexer in a site.

Before you begin

Log in to Cisco ONP Web Interface.

Procedure


Step 1

In the network tree, Choose Sites > Site > Site domain > Side > L-Band.

Step 2

To modify the Add/Drop multiplexer card properties, perform the following steps:

  1. Click Add/Drop.

    You can view the properties of the add/drop multiplexer at the bottom of the network tree.
  2. Modify the following properties of the add/drop multiplexer:

    You can also modify the properties by choosing the Add/Drop under Network > Entity Editor.

    Options

    Platform

    Description

    General

    Colorless Add/Drop

    NCS 1010

    The options available for NCS 1010 are:

    • Auto

    • None

    • BRK-8

    • BRK-16

    • BRK-24

    Note

     

    Only L-band optical sources are supported. Pluggables are not supported in L-band networks.

    Colorless Ports

    NCS 1010

    Enter the number of colorless ports. The default values is 0. If you do not change the default value, Cisco ONP automatically calculates the number of colorless ports based on the number of circuits added and colorless add/drop units forced.

  3. Click Update.


Modify Client Properties

Use this task to modify the properties of a client-side attenuator in a site.

Before you begin

Table 12. Feature History

Feature Name

Release Information

Feature Description

Channel Attenuators

Cisco ONP Release 4.2

You can set up channel attenuators for QSFP-DD demands. You can choose different channel attenuators based on the specific configuration and check for the optical feasibility of the channel.

Log in to Cisco ONP Web Interface

Procedure


Step 1

In the network tree, choose Sites > Site > Site domain > Side > Clients > Channel-Attenuators.

Step 2

In the right pane of the Entity Editor window, modify the following properties of the client-side attenuator.

Properties

Platform

Description

General

Wavelength

NCS 2000

This column displays the selected wavelength.

RX-Attenuator

NCS 2000

Choose an RX-Attenuator from the drop-down list. The default option is Auto.

Note

 

You must select a wavelength to edit this field.

TX-Attenuator

NCS 2000

Choose a TX-Attenuator from the drop-down list. The default option is Auto.

Note

 

You must select a wavelength to edit this field.

New Wavelength - Auto

NCS 2000

Click Edit to select a Flex Grid or Fixed Grid wavelength.

Note

 

Select Fixed Grid (64-Chs) for SSON network with NCS1K-MD-64-C card.

Note

 

NCS1K-MD-64-C card has First Channel limitation for Colored sites. First Channel (196.1 THz) in Fixed Grid (64-Chs) wavelength supports only Terminal Add/Drop sites and not ROADM sites.

Step 3

Click Update.


Sort the Network Elements

You can sort the sites, services, fibers, waves, and SRLG in ascending or descending order. This feature is helpful for huge networks, to find out the required site, fiber, waves, or SRLG names quickly. Right-click the network element, for example Sites and choose Ascending or Descending. You can sort based on alphabets, numbers, or alphanumeric.

Regeneration Support

In optical networks, as the fiber length increases, a loss in the signal ratio and power could occur due to attenuation and dispersion. You require a regenerator to recreate the weak and distorted optical signals through reamplification, regeneration, and retiming processes. The regenerators remove noise and distortion, convert the optical signal to electrical signal, and then convert the signals back to optical signals (OEO conversion). Cisco ONP supports creation of regeneration sites in the network.


Note


A regenerator site can only be a ROADM site.


Create a Regeneration Site

Table 13. Feature History

Feature Name

Release Information

Feature Description

Wavelength Forcing at the Section Level

Cisco ONP Release 4.1

This feature allows you to assign different wavelengths for different sections of the Regen sites.

Use the following procedure to create a regeneration site in the network.

Before you begin

Log in to Cisco ONP Web Interface.

Procedure


Step 1

Choose File > Open.

The Select Network To Open dialog box appears.

Step 2

Select a network from the list of networks. This opens the selected network’s map.

You can also add a regeneration site when you are designing a new network or upgrading a network.

Step 3

In the network tree, expand Waves, select a wave and drill down to its trail.

Note

 

If the network is an SSON network or NCS 1010 network, you see Media Channels or Circuits respectively. instead of waves. Expand Media Channels or Circuits , and drill down to its trail.

Step 4

Click the trail.

You can view the properties of the trail at the bottom of the network tree.

Step 5

From the Regen Sites drop-down list, select a regeneration site.

Note

 

If you select a fiber from the Path of Wave drop-down list, you cannot select any regeneration site to force a path. Similarly, if you select a regeneration site, you cannot force a path for the wave. However, if you want to force a fiber, select the fiber from the Path of Wave drop-down list available under the section properties.

Step 6

(Optional) Select the wavelength of each section in the properties for non-SSON network.

Note

 

For the SSON network, you can select the wavelength only at the trial level.

Step 7

Click Update.

A new section is added along with the existing section under the trail, whenever a regeneration site is created. Regeneration can be performed using any two cards back-to-back or with a dedicated regenerator card.

Step 8

Click Analyze to analyze the network.

After analysis, if you click trail or section in the network tree, the map highlights the trail in orange color, and the section in green color.

Note

 

You can assign different wavelengths for different sections. The Central Wavelength is denoted as a *, when different wavelengths are assigned for different sections.


Multidegree ROADM

In multidegree ROADM, sites have two or more sides and face two or more fibers spans. You can select the degree of a node from the Cisco ONP GUI. The values are 2, 4, 8, 12, and 16 for Evolved Mesh (EV) ON and OFF scenarios. The default value is 4. Degrees 5, 9, and 13 are not supported. EV flag is editable.

Prerequisites for Cascaded SMR

  • The Structure field under C Band in the Entity Editor must be Multidegree.

  • The Site Type field under C Band in the Entity Editor must be SMR-20.

  • The Evolved Mesh check box under General in the Entity Editor must be checked.

  • The Degree Mesh Type field under C Band in the Entity Editor must be Auto or DEG-5/UPG-4.

  • The Mpo16TOMpo8 field under General in the Entity Editor must be MPO16To2MPO8 cable.

  • By default, the Cascaded SMR check box is unchecked, but you can edit in the design mode as a site property. Check the Cascaded SMR check box for contentionless side creation. L2 SMR is supported for both SSON and Non-SSON networks.

  • You can edit the Cascaded SMR check box when Evolved Mesh is ON and the SMR-20 card is selected. You can create Layer 2 SMR sides only after you check the Cascaded SMR check box.

  • You can create contentionless sides manually and force the contentionless ports. The default value is 16 for the contentionless ports. The range of values is 0–16.

Limitations

  • Supports only contentionless add/drop demands.

  • Supports Layer-2 SMR for SMR-20 card only.